EDAS-24GN Universal Earthquake Data Acquisition Server

Item No.: EDAS-24GN
Proposed Price:
USD$ ****
Description Technical Parameter Verified Information
PROPOSED PRICE
USD$ ****
Notice
This quotation is for reference only. Please consult the company if you are interested. The quotation only represents the cost of the instrument and does not include installation and commissioning.
 
BRIEF INTRODUCTION
EDAS-24GN is a general seismic data collection and recording equipment which is high in resolution, large in dynamic range, capable of outputting low-latency real-time data flow and suitable for being used in seismic observation station, earthquake early warning station and comprehensive seismic observation station. It can convert the input of multichannel analog voltage and frequency into digital output and has the functions of data collection, data recording and network data/serial port data transmission. It is also in support of mass data storage and has the features of small size, light weight and low power consumption.
MAIN APPLICATIONS
EDAS-24GN is a general seismic data collection and recording equipment which is high in resolution, large in dynamic range, capable of outputting low-latency real-time data flow and suitable for being used in seismic observation station, earthquake early warning station and comprehensive seismic observation station. It can convert the input of multichannel analog voltage and frequency into digital output and has the functions of data collection, data recording and network data/serial port data transmission. It is also in support of mass data storage and has the features of small size, light weight and low power consumption.
MAIN FEATURES
 
With high-speed data output in 50 times per second, it is suitable for seismic observation and early warning study;
 
Multiple collection channels can output voltage measuring results of 12 paths and frequency measuring results of 3 paths simultaneously;
 
Simultaneous output of multiple sampling rate data (1, 2, 10, 20, 50, 100, 200, 500) can be achieved;
 
FIR digital filter with built-in linear phase and min phase characteristics;
 
24-bit high-precision AD conversion is adopted, and the dynamic range is larger than 135dB;
 
The equal-precision measuring frequency is adopted so as to ensure consistency of measurement accuracy;
 
It is based on networking function of TCP/IP protocol and in support of long-distance parameter setting, data transmission, downloading and long-distance firmware upgrade;
 
A mass storage device records continuous data and event data;
 
The IRIG-B code time service system is GPS-enabled and Plough time service network enabled, and the precision of simultaneous system clock is less than 0.1millisecond;
 
It is provided with loop self-checking function.
 
TECHNICAL PARAMETER

Technical parameters

Contents

 Technical parameters

 Contents

Seismic data collection channel

Number of data collection channel

3/6 seismic detection/macroseism/forewarning data collection channels

3/6 forewarning data collection channels

3 frequency data collection channels

 Precursor  collection channel

Full-scale value of input signal

±10V,Double-end balanced differential input

 Full-scale value of input signal

±2.5V, ±5V,±10V or ±20V, Double-end balanced differential input

 Input impedance

1MΩ(single edge)

 Input impedance

500KΩ(single edge)

A/D conversion

24 bit

A/D conversion

24 bit

Dynamic range

>135dB @ 1Hz sampling frequency 

 Dynamic range

>135dB @ 50Hz sampling rate

 Interval of real-time data output

1second

 System noise

less than 1LSB(effective value)

 Local record format

 Compressed format or forewarning instrument data format

 Non-linear distortion degree

<-110dB @ 50Hz sampling rate

Frequency measurement channel

 Measurement range

10Hz~200KHz

 

Inter channel crosstalk

<-110dB

 Measurement accuracy

Output data*10-6

Passband fluctuation

<0.1dB

Resolution

5*10-7

 Extrinsic attenuation of passband

>135dB

 Input impedance

1MΩ

Digital filter

FIR digital filter with settable linear phase shift and minimum phase shift

Local record format

 Compressed format or forewarning instrument data format

Output sampling rate

1, 10, 20, 50, 100, 200 and 500Hz

 Interval of real-time data output

1second

Various sampling rate output

 Each channel supports simultaneous output of various sampling rate data.

Output unit and dimension

Hz

Minimum output interval of real-time data

10 sampling sites/bag(Low-latency real-time data is provided for serving earthquake early warning.)

 Degree of stability of measurement time base

10-8,when the GPS module is synchronous

 High-pass filtering

 DC, 10, 30, 100, 300, 1000 and 3000S can be set

Time service

Timing accuracy

When GPS module is synchronous, the clock precision is less than 0.1ms

 

Calibration signal generator

16-bit DAC,program-controlled waveform output, ±10mA

Punctuality accuracy

 When GPS module is not synchronous, the clock drift is less than 1ms/day

Loop self-checking

Analog channel input can be connected to the calibration output or signal ground in a program control mode..

Timing input

IRIG-B code time signal,in support of GPS and Plough time service system

Calibration signal type

Square wave and sine wave, pseudorandom binary code signal frequency, amplitude and period number can be set.

Accessory GPS module

Time signal output of IRIG-B code

Local record format

EVT, optional compressed format,in support of Mini SEED format

Communication

 Communication interface

Two RS232C serial ports,one standard 10M/100M ethernet card

Record function

Supporting simultaneous record of continuous data and trigger event data

 Communication protocol

Supporting TCP/IP, FTP, Telnet, Http, etc.

VERIFIED INFORMATION
Notice
This information was Verified by TÜV Rheinland and is valid for the following period: 2020/05/28 --- 2021/05/27
The information below covers both the Gold Supplier and its related companies, which are defined according to china laws and regulations, and which will also be clearly displayed in the full report >>
THE COMPETIVE ADVANTAGE OF PRODUCT LINE
The company has experienced foreign trade team and perfect after-sales service, strictly implement the requirements of quality management system, and provide customers with high quality products.
PRODUCTION CAPACITY
Product Line Name Production Line Capacity Actual Units Produced(Previous Year)
Equipment; Digital Seismograph; Date Acquisition Server; Vibration Tester; Software Equipment; Digital Seismograph; Date Acquisition Server; Vibration Tester; Software: 1,000 Pieces / Month confidential
EXPORT MARKET DISRTIBUTION
Market Revenue(Previous Year) Total Revenue (%)
North America confidential 3.0
South America confidential 0.0
Eastern Europe confidential 0.0
Southeast Asia confidential 1.0
Africa confidential 0.0
Oceania confidential 0.0
Mid East confidential 0.0
Eastern Asia confidential 0.0
Western Europe confidential 0.0
Central America confidential 0.0
Northern Europe confidential 0.0
Southern Europe confidential 0.0
PRODUCTION MACHINERY
Machine Name Brand & Model No. Quantity Number of Year(s) Used Condition
Assembly Table No Information 20 3.0 Acceptable
Hardware Tools No Information 20 3.0 Acceptable
Soldering Machine No Information 20 3.0 Acceptable
TEXTING MACHINERY
Machine Name Brand & Model No. Quantity Number of Year(s) Used Condition
Assembly Table No Information 20 3.0 Acceptable
Hardware Tools No Information 20 3.0 Acceptable
Soldering Machine No Information 20 3.0 Acceptable
REAL CASE FOR LOWER MOQ
Products Name MOQ(in the last 12month)
Confidential Confidential
REAL CASE FOR LARGE CONTRACT
Products Name MOQ(in the last 12month)
Confidential Confidential
PRODUCTION CAPACITY
Product Line Name Order(in the last 12month) Shortest Lead Time
Confidential Confidential Confidential

Technical parameters

Contents

 Technical parameters

 Contents

Seismic data collection channel

Number of data collection channel

3/6 seismic detection/macroseism/forewarning data collection channels

3/6 forewarning data collection channels

3 frequency data collection channels

 Precursor  collection channel

Full-scale value of input signal

±10V,Double-end balanced differential input

 Full-scale value of input signal

±2.5V, ±5V,±10V or ±20V, Double-end balanced differential input

 Input impedance

1MΩ(single edge)

 Input impedance

500KΩ(single edge)

A/D conversion

24 bit

A/D conversion

24 bit

Dynamic range

>135dB @ 1Hz sampling frequency 

 Dynamic range

>135dB @ 50Hz sampling rate

 Interval of real-time data output

1second

 System noise

less than 1LSB(effective value)

 Local record format

 Compressed format or forewarning instrument data format

 Non-linear distortion degree

<-110dB @ 50Hz sampling rate

Frequency measurement channel

 Measurement range

10Hz~200KHz

 

Inter channel crosstalk

<-110dB

 Measurement accuracy

Output data*10-6

Passband fluctuation

<0.1dB

Resolution

5*10-7

 Extrinsic attenuation of passband

>135dB

 Input impedance

1MΩ

Digital filter

FIR digital filter with settable linear phase shift and minimum phase shift

Local record format

 Compressed format or forewarning instrument data format

Output sampling rate

1, 10, 20, 50, 100, 200 and 500Hz

 Interval of real-time data output

1second

Various sampling rate output

 Each channel supports simultaneous output of various sampling rate data.

Output unit and dimension

Hz

Minimum output interval of real-time data

10 sampling sites/bag(Low-latency real-time data is provided for serving earthquake early warning.)

 Degree of stability of measurement time base

10-8,when the GPS module is synchronous

 High-pass filtering

 DC, 10, 30, 100, 300, 1000 and 3000S can be set

Time service

Timing accuracy

When GPS module is synchronous, the clock precision is less than 0.1ms

 

Calibration signal generator

16-bit DAC,program-controlled waveform output, ±10mA

Punctuality accuracy

 When GPS module is not synchronous, the clock drift is less than 1ms/day

Loop self-checking

Analog channel input can be connected to the calibration output or signal ground in a program control mode..

Timing input

IRIG-B code time signal,in support of GPS and Plough time service system

Calibration signal type

Square wave and sine wave, pseudorandom binary code signal frequency, amplitude and period number can be set.

Accessory GPS module

Time signal output of IRIG-B code

Local record format

EVT, optional compressed format,in support of Mini SEED format

Communication

 Communication interface

Two RS232C serial ports,one standard 10M/100M ethernet card

Record function

Supporting simultaneous record of continuous data and trigger event data

 Communication protocol

Supporting TCP/IP, FTP, Telnet, Http, etc.

EDAS-24GN Universal Earthquake Data Acquisition Server

EDAS-24GN Universal Earthquake Data Acquisition Server


Verified Information

This information was Verified by  TÜV Rheinland and is valid for the following period: 2020/05/28 --- 2021/05/27
The information below covers both the Gold Supplier and its related companies, which are defined according to china laws and regulations, and which will also be clearly displayed in the full report >>


The competitive advantage of product line:

The company has experienced foreign trade team and perfect after-sales service, strictly implement the requirements of quality management system, and provide customers with high quality products.


Production Capacity:

Product Line Name Production Line Capacity Actual Units Produced(Previous Year)
Equipment; Digital Seismograph; Date Acquisition Server; Vibration Tester; Software Equipment; Digital Seismograph; Date Acquisition Server; Vibration Tester; Software: 1,000 Pieces / Month confidential


Export Market Distribution:

Market Revenue(Previous Year) Total Revenue (%)
North America confidential 3.0
South America confidential 0.0
Eastern Europe confidential 0.0
Southeast Asia confidential 1.0
Africa confidential 0.0
Oceania confidential 0.0
Mid East confidential 0.0
Eastern Asia confidential 0.0
Western Europe confidential 0.0
Central America confidential 0.0
Northern Europe confidential 0.0
Southern Europe confidential 0.0
South Asia confidential 3.0
Domestic Market confidential 93.0


Production Machinery:

Machine Name Brand & Model No. Quantity Number of Year(s) Used Condition
Assembly Table No Information 20 3.0 Acceptable
Hardware Tools No Information 20 3.0 Acceptable
Soldering Machine No Information 20 3.0 Acceptable


Testing Machinery:

Machine Name Brand & Model No. Quantity Number of Year(s) Used Condition
Aging Test Bench No Information 3 3.0 Acceptable
Horizontal Vibration Test Bench No Information 1 3.0 Acceptable
Vertical Vibration Test Bench No Information 1 3.0 Acceptable
 

Real Case for Lower MOQ:

Products Name MOQ(in the last 12month)
Confidential confidential


Real Case for Large Contract:

Products Name Order(in the last 12month)
Confidential confidential


Short Lead Time:

Products Name Order(in the last 12month) Shortest Lead Time
Confidential confidential confidential